One one side of the flat roof there was a shingled roof joining into the flat roof, on the other side by the edge of the roof was a small scupper that wasn’t really being very effective. There were two issues with the roof due to its design, in the winter time there was about 4 feet of snow sitting on it which was an issue because of the transition between the flat and singled roof, and when it rained, the water on the roof would just pool. The roof didn’t get much sunlight so the water wasn’t evaporating and we were called in to make a recommendation and take care of the roof.

Our plan was to taper the roof towards a new, more capable scupper so all water would drain off the roof immediately, and we wanted to put a rock solid seal in the transition to the shingled roof.

We removed all the stones off the roof and dried the roof out. We put down 1/2 inch fibreboard, and 1/8” sopaboard to direct the water towards the new scupper we put in. We put a new scupper in so it can handle more water drainage and the home owner can put a new downspout on. Because we had to elevate the section we had to put new wood around the perimeter, it gives us something to adhere the cap sheet to and put the metal flashing around.

We removed the first 3 layers of shingles and we took the new membrane over the top of the felt, then put shingles over the top of the new membrane to prevent any water getting into the roof. Then we reshingled the roof.

We’re really pleased with the way the whole project went, the homeowner is going to have many years of trouble free usage out of his roof.

You can see what the client thought about the project here.